Made from pure cellulose nitrate
Types AE and NC
- For prefiltration and dust measurement, clarification and sterilizing filtration
- Very easily wetted
- For aqueous solutions
- Hydrophilic
- Can be used up to 125°C
- Can be autoclaved at up to 121°C
- Large range of applications with six different pore sizes between 0.1 µm and 12 µm.
Product Selection
Type |
Nominal
pore size µm |
Thickness
µm |
Water flow rate
p = 0.9 bar ml/min/cm2 |
Air flow rate
p = 3 mbar ml/min/cm2 |
Bubble
point bar |
NC-10 |
0.1
|
105
|
5
|
–
|
7
|
NC-20 |
0.2
|
140
|
20
|
–
|
4
|
NC-45 |
0.45
|
140
|
40
|
25
|
3
|
AE-98 |
5
|
120
|
530
|
230
|
0.5
|
AE-99 |
8
|
120
|
800
|
335
|
0.48
|
AE-100 |
12
|
115
|
1000
|
615
|
0.2
|